Polyamide 66 /Glass filled/ – PA66 GF30
DIN abbreviation: PA 66 GF30
Short description of material
This extruded polyamide has good hardness, stiffness and wear resistance but worse impact resistance. The properties of PA 66 are comparable to PA 6 G, however PA 66 absorbs more moisture and is less dimensionally stable.
Application examples:
- Component parts with a higher demand for dimensional stability and /or higher loads.
Colours: Black
ТЕХНИЧЕСКИ ХАРАКТЕРИСТИКИ
Material standard values | Method | Dry | Humid | Measure |
Mechanical values | ||||
Density | ISO 1183 | 1.35 | g/cmᶾ | |
Yield stress | ISO 527 | 160 | – | Mpa |
Elongation due to tearing | ISO 527 | 3 | 3 | % |
Modulus of elasticity resulting from tensile test | ISO 527 | 11.000 | – | Mpa |
Modulus of elasticity resulting from bending test | ISO 178 | – | – | Mpa |
Flexural strenght | ISO 178 | – | – | Mpa |
Impact strenght ₁ | ISO 179 | 50 | – | KJ/m² |
Notched-bar impact strength | ISO 179 | 6 | 6 | KJ/m² |
Ball indentation hardness H358/30 | ISO 2039-1 | 240 | 200 | MPa |
Creep rate stress at 1% alongation ₂ | DIN 53 444 | 40 | Mpa | |
Sliding friction coefficiet against steel ₃ | – | 0.45 | 0.5 | |
Sliding wear against steel ₃ | – | – | μm/km | |
Thermal values | ||||
Melting temperature | ISO 3146 | 255 | °C | |
Thermal conductivity | DIN 52 612 | 0.3 | W/(K*m) | |
Specific thermal capacity | – | 1.5 | 1.5 | J/(g*K) |
Coefficient of linear expansion ₄ | – | 2 ‒ 3 | 10-5*K-1 | |
Operating temperature range (longterm) ₅ | – | – 30 / + 120 | °C | |
Operating temperature range (short-term) ₅ | – | 180 | °C | |
Fire behaviour | UL 94 | HB | – | |
Electrical values | ||||
Dielectric constant ₆ | IEC 250 | 3.7 | – | |
Dielectric loss factor ₆ | IEC 250 | 0.02 | – | |
Specific volume resistance | IEC 93 | 1014 | 1013 | Ω*cm |
Surface resistance | IEC 93 | 1013 | 1012 | Ω |
Dielectric strenght | IEC 243 | 60 | 30 | KV/mm |
Creep current resistance | IEC 112 | CTI 475 | – | |
Miscellaneous data | ||||
Moisture absorption in normal climate until saturated | DIN 53 715 | 1.5 | % | |
Water absorption until saturated | ISO 62 | 5.5 | % |
₁ – Measured with pendulum impact testing machine 0,1 DIN 51 222
₂ – Tension resulting in 1% total elongation after 1000h
₃ – Against steel, hardened and ground: P=0.05 Mpa, V=0.6 m/s, t=60 °C
₄ – For temperature range of +23 до +60 °C
₅ – Short-term = max 1 h; long-term = months
₆ – at 10⁶ Hz
1 Mpa= 1 N/mm2
1 g/cm3=1.000 kg/m3
1 kV/mm=1 Mv/m
Please contact us for further information